Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump

After-sales Service: on-Site&on-Line Service
Warranty: 12 Months
Max.Head: 80-110m
Max.Capacity: >400 L/min
Driving Type: Motor
Impeller Number: Multistage Pump
Samples:
US$ 800/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Shandong, China
  • Overview
  • Product Description
  • Packaging & Shipping
  • Application
  • FAQ
  • Related Products
Overview

Basic Info.

Model NO.
CAM, CNF
Working Pressure
High Pressure Pump
Influent Type of Impeller
Single Suction Pump
Position of Pump Shaft
Horizontal Pump
Pump Casing Combined
Horizontal Split Pumps
Mounting Height
Suction Centrifugal
Impeller
Closed
Usage
Pumps
Applicable Medium
Ammonia, Freon, CO2, Silicon Oil
Rated Pressure
1-10 MPa
Applicable Temperature
-100~+40
Material
Carbon Steel, Stainless Steel
Original
Dalian Hermetic
Spare Parts
Available
Transport Package
Wooden Case
Specification
CNF, CAM
Trademark
Hermetic
Origin
China
HS Code
8413709990
Production Capacity
1200PCS/Year

Product Description

 
Product Description

Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump

Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump
Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump


Hermetic refrigeration pump is a combination unit of centrifugal pump and 3-phase AC motor, with the hydraulic section connecting directly with the motor drive shaft to constitute the rotor component jointly. The stator can is embedded on the inner side of the stator to isolate both the rotor chamber and stator chamber, that makes Hermetic pumps sealless completely. When the pump is operating, the axial force is balanced automatically and hydraulically. 
The stator can is imported from Germany, that is formed by rolling in a special process to have a high precision, a good quality free from wedling defects, that ensures sufficiently the canned motor pump to operate reliably and stably. 
The slide bearing is in FH82A to have such advantages as high strength, good wear resistance, etc, and a service life 10 times more than resin impregnated graphite bearing. 
Hermetic refrigeration pump consists of CNF series and CAM/CAM2 series, in which CNF series is in a horizontal single-stage structure and CAM1/CAM2 in a horizontal multi-stage structure, and both are in the form of axial suction, radial discharge. 

Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump
Refrigeration Pump Series CAM1/CAM2
Structural characteristics: 

Series CAM1/CAM2 refrigeration pump is one with multi-stage and in a high pressure intermal circultation mode. Part of medium is diverted from the high pressure zone at the impeller outlet in the final stage, and capacitys through the filter net into the rotor chamber of canned motor, and returns through the shaft central hole to the hypo-high-pressure impeller zone in the next final stage. This kind of high pressure internal circulation mode ensures sufficiently the pressure in the rotor chamber of the canned motor to keep media from vaporizing in the pump. That diversion also has a function of cooling the canned motor, lubricating the slide bearing. When the pump is operating, the axial force is balanced automatically and hydraulically. The NPSHr is very low, and when the capacity is as high as 10m3/h, it is only 0.8m for the pump. 
Refrigeration Pump Series CNF
Structural characteristics: 

Series CNF refrigeration pump is one with a single stage and in a high pressure internal circulation mode. Part of medium is diverted from the high pressure zone at the impeller outlet, and capacity through a filter net into the shaft central hole, where it is further pressurized by the auxiliary impeller before coming into the rotor chamber of the canned motor, and finally, it returns to the high-pressure zone at the impeller outlet. This kind of high pressure internal circulation mode ensures sufficiently the pressure in the rotor chamber of the canned motor to keep media from vaporizing in the pump. That diversion also has a function of cooling the canned motor, lubricating the slide bearing
Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump
Structure Brand Model No. Capacity (Q)
Single Stage Hermetic CNF 4-70m3/h
       
Head Lift Rated Temp. Pressure Grad  
Max.100m -50 ºC ~ + 30 ºC PN25  

 

Packaging & Shipping

Packing: Each pump will be packed into one single wooden case. 
Shipping: Multiple shipping methods available, sea shipping, air  shipping, railway transportation, etc. 

Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump
Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump
Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump

 

Application

Hermetic Refrigeration Pump is used in the refrigeration industry for delivering refrigerants such as liquid ammonia(R717), Freon(R22/R12), silicon oil, CO2, etc.

Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump
FAQ

Q: What's the lead time for pumps? 
A: Usually 40-50 days after the deposit, depending on order quantity

Q: What's the payment term? 
A: T/T or L/C. 

Q: What kind of shipping methods available? 
A: Sea, Air, Railway transportaion are all available. 

Related Products
Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump
Single and Multi Stage Ammonia Refrigeration Original Hermetic Pumpen Canned Motor Pump

                                             CNF Series                                                                                  CAM Series

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now